Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Rev. gaúch. enferm ; 43: e20210071, 2022. tab
Article in English | LILACS-Express | LILACS, BDENF | ID: biblio-1376952

ABSTRACT

ABSTRACT Objective: To investigate infusion pumps start-up delay according to different brands of infusion pumps, flow rates and intravenous sets priming techniques. Method: The experimental study simulated clinical practice under controlled conditions, using a 50 mL syringe with NaCl 0.9% solution, two syringe infusion pumps (A and B), six rates (0.3, 0.5, 1.0, 5, 10 and 20 mL/h), two purging techniques (manually or infusion pump's electronic bolus). Data were analyzed according to mean, standard deviation, Student's t and ANOVA tests (p<0.05). Results: The start-up delay was greater in low rates regardless the priming technique. The electronic bolus increased the infusion pump A accuracy at 0.3mL/h (p=0.010), 0.5 mL/h (p=0.002) and 1.0mL/h (p=0.004). Pump's accuracy in all studied rates and manual IV sets filling was similar. Conclusion: In low infusion rates the start-up delay was greater despite the infusion pump brand and electronic bolus improved pumps accuracy.


RESUMEN Objetivo: El objetivo fue investigar el retraso en la operación de bombas de infusión de acuerdo con diferentes marcas de bombas de infusión, velocidades de infusión y técnicas de purga de lo sistema de infusión. Método: Estudio experimental que simuló la práctica clínica en condiciones controladas con jeringas de 50 mL y solución de NaCl 0,9%, dos bombas de infusión de jeringa (A y B), seis velocidades (0,3; 0,5; 1,0; 5; 10 y 20 mL/h), dos modos de purga (manual o electrónico por la bomba de infusión - bolo). Los datos se analizaron según media, desviación estándar, Test-T y ANOVA (p<0,05). Resultados: El retraso de la operación de las bombas ocurrió en tasas bajas independientemente de la técnica de purga. El modo electrónico aumentó la precisión de la bomba de infusión A en 0,3 mL/h (p=0,010), 0,5 mL/h (p = 0,002) y 1,0 mL/h (p=0,004). Con la técnica manual la precisión fue similar. Conclusión: Los retrasos de operación fueran significantes en bajas velocidades de infusión y el modo electrónico optimizó la precisión.


RESUMO Objetivo: Verificar o atraso de inicialização de bomba de infusão, segundo diferentes marcas de bombas de infusão, velocidades e técnicas de preenchimento do sistema de infusão intravenosa. Método: Estudo experimental que simulou a prática clínica, utilizando seringas de 50 mL com solução de NaCl 0,9%, duas marcas de bombas de infusão por seringa (A e B), seis velocidades (0,3; 0,5; 1,0; 5; 10 e 20 mL/h), dois modos de preenchimento do sistema (manual ou eletrônico pelo modo bolus do equipamento). Os dados foram analisados segundo média, desvio padrão e testes t de Student e ANOVA (p<0,05). Resultados: O atraso na inicialização foi maior em velocidades baixas, independentemente da marca e modo de preenchimento. O preenchimento eletrônico aumentou a acurácia na bomba A em 0,3 mL/h (p=0,010), 0,5 mL/h (p=0,002) e 1,0 mL/h (p=0,004). A acurácia em preenchimento manual foi semelhante. Conclusão: Em baixas velocidades de infusão o atraso de inicialização foi maior e o preenchimento do sistema de infusão pelo modo eletrônico melhorou a acurácia dos equipamentos.

2.
Rev. Esc. Enferm. USP ; 55: e03712, 2021. tab, graf
Article in English | BDENF, LILACS | ID: biblio-1250729

ABSTRACT

ABSTRACT Objective: To analyze the usability of two infusion pump models in a Pediatric Intensive Care Unit. Method: This is a cross-sectional study of exploratory descriptive quantitative approach. A task was carried out in a controlled environment using infusion pump with 72 nursing staff members from August to September 2018. The Methodological Guideline for Medical Care Equipment Assessment Studies and the quality model proposed by NBR ISO/IEC 9126-1 were followed. Descriptive statistical analysis was used applying Fisher's exact test, binomial test and Mann-Whitney test. Results: 91.7% of tasks were completed. The infusion pump-2 model was associated (p < 0.001) with operationalization, tasks accomplished with non-conformities, use of a manual calculator (measure effectiveness) and task accomplishment time (measure efficiency). Conclusion: Efficacy and efficiency measures can evidence a better context of usability of IPs and identify interaction failures with the nursing staff to be improved in care practice.


RESUMEN Objetivo: Analizar la usabilidad de dos modelos de bombas de infusión en una Unidad de Cuidados Intensivos Pediátricos. Método: Estudio transversal con abordaje descriptivo exploratorio cuantitativo. Se realizó una tarea en ambiente controlado utilizando la bomba de infusión con 72 integrantes del equipo de enfermería de agosto a septiembre de 2018. Como base, se siguió la guía metodológica para los estudios de evaluación de Equipos de Asistencia Médica y el modelo de calidad en uso propuesto por NBR ISO/IEC 9126-1 Se utilizó análisis estadístico descriptivo, aplicando Test Exacto de Fisher, Test Binomial y Test de Mann-Whitney. Resultados: Hubo 91,7% de tareas completadas. El modelo de bomba de infusión-2 se asoció (p <0,001) con la operatividad, las tareas cumplidas con no conformidades, el uso de la calculadora manual (medida de efectividad) y el tiempo para completar la tarea (medida de eficiencia). Conclusión: Las medidas de eficacia y eficiencia pueden mostrar un mejor contexto de usabilidad de las bombas de infusión e identificar fallas de interacción con el equipo de enfermería para mejorar en la práctica asistencial.


RESUMO Objetivo: Analisar a usabilidade de dois modelos de bomba de infusão em Unidade de Terapia Intensiva Pediátrica. Método: Estudo com delineamento transversal de abordagem quantitativa do tipo descritivo exploratório. Realizou-se em um ambiente controlado uma tarefa utilizando a bomba de infusão com 72 integrantes da equipe de enfermagem no período de agosto a setembro de 2018. Como base, seguiu-se a diretriz metodológica para estudos de avaliação de Equipamentos Médicos-Assistenciais e o modelo de qualidade em uso proposto pela NBR ISO/IEC 9126-1. Utilizou-se a análise estatística descritiva, aplicando o Teste Exato de Fisher, o Teste Binomial e o Teste de Mann-Whitney. Resultados: Constataram-se 91,7% de tarefas cumpridas. O modelo da bomba de infusão-2 apresentou associação (p < 0,001) com a operacionalização, tarefas cumpridas com não conformidades, uso da calculadora manual (medida eficácia) e o tempo para cumprir a tarefa (medida eficiência). Conclusão: Medidas de eficácia e eficiência podem evidenciar um melhor contexto de usabilidade de bombas de infusão e identificar falhas de interação com a equipe de enfermagem a serem aprimoradas na prática assistencial.


Subject(s)
Pediatric Nursing , Intensive Care Units, Pediatric , Quality of Health Care , Technology Assessment, Biomedical , Infusion Pumps , Ergonomics
3.
Rev. Pesqui. (Univ. Fed. Estado Rio J., Online) ; 13: 1428-1435, jan.-dez. 2021. ilus
Article in English, Portuguese | LILACS, BDENF | ID: biblio-1342109

ABSTRACT

Objetivo: identificar as causas da fadiga de alarmes em estudos de usabilidade de bomba de infusão em terapia intensiva pediátrica. Métodos: Realizou-se uma revisão integrativa nas bases de dados LILACS, SciELO, IBECS, SCOPUS e MEDLINE. Resultados: Foram identificadas 1.164 publicações e selecionados seis estudos primários que emergiram em duas temáticas: compreender as causas dos alarmes da bomba de infusão que constou: biblioteca de fármacos incompleta, limites absolutos e relativos rígidos, falta de protocolo de preparo e administração de medicação, período de férias dos funcionários; e as medidas que podem evitar a fadiga de seus alarmes.Conclusão:falhas na usabilidade de bombas de infusão aumentam os alarmes desnecessários que podem promovem sua fadiga. A utilização segura de bombas de infusão demanda uma equipe que monitore suas práticas e atue promovendo mudanças no contexto de trabalho


Objective: to identify the causes of alarm fatigue in studies of infusion pump usability in pediatric intensive care. Methods: an integrative review was carried out in the LILACS, SciELO, IBECS, SCOPUS and MEDLINE databases. Results: 1,164 publications were identified and six primary studies were selected that emerged in two themes: understanding the causes of the infusion pump alarms that consisted of: incomplete drug library, absolute and strict relative limits, lack of preparation protocol and medication administration, employee vacation period; and measures that can prevent fatigue from your alarms. Conclusion: the causes of alarm fatigue involve low user interaction with the equipment, inadequate work processes and low investment in preventive measures for its occurrence The safe use of infusion pumps requires a team to monitor their practices and act by promoting changes in the work context


Objetivo: identificar las causas de la fatiga de alarma en estudios de usabilidad de bombas de infusión en cuidados intensivos pediátricos. Métodos: se realizó una revisión integradora en las bases de datos LILACS, SciELO, IBECS, SCOPUS y MEDLINE. Resultados: se identificaron 1.164 publicaciones y se seleccionaron seis estudios primarios que surgieron en dos temas: comprender las causas de las alarmas de la bomba de infusión que consistían en: biblioteca de medicamentos incompleta, límites relativos absolutos y estrictos, falta de protocolo de preparación y administración de medicamentos, período de vacaciones de los empleados; y medidas que pueden prevenir la fatiga de sus alarmas. Conclusión: las causas de la fatiga de las alarmas involucran baja interacción del usuario con el equipo, procesos de trabajo inadecuados y baja inversión en medidas preventivas para su ocurrencia. El uso seguro de las bombas de infusión requiere que un equipo monitoree sus prácticas y actúe promoviendo cambios en el contexto de trabajo


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Infusion Pumps/standards , Intensive Care Units, Pediatric , Alert Fatigue, Health Personnel/prevention & control , Occupational Stress/prevention & control
4.
Rev. enferm. UFSM ; 10: 32, 2020.
Article in English, Portuguese | BDENF, LILACS | ID: biblio-1119321

ABSTRACT

Objetivo: analisar as percepções dos profissionais de enfermagem sobre o uso da Bomba de Infusão no seu cotidiano em Terapia Intensiva. Método: estudo descritivo-exploratório de abordagem qualitativa, realizado com 15 profissionais de enfermagem da Unidade de Terapia Intensiva Adulto de um hospital-escola público do Paraná. A coleta de dados ocorreu em junho/2017, por meio de entrevistas semiestruturadas gravadas, pautadas na questão norteadora: fale-me sobre o uso da bomba de infusão no seu cotidiano de trabalho. Aos dados transcritos, empregou-se a Análise de Conteúdo. Resultados: foram pontuados aspectos positivos e negativos acerca do uso da bomba de infusão, além de sugestões gerais ao seu propósito. Considerações Finais: apesar dos entrevistados perceberem a Bomba de Infusão como viabilizadora da assertividade na infusão volêmica, existem desvantagens relacionadas ao sensor de gotas e alarme. Como sugestões de melhorias, referiam necessidade de otimizar o design da Bomba de Infusão, especialmente a programação de alarmes.


Objective: to analyze the perceptions of nursing professionals about the use of the Infusion Pump in their daily lives in Intensive Care. Method: descriptive-exploratory study, with a qualitative approach, conducted with 15 nursing professionals working in the Intensive Care Unit for Adults of a public teaching hospital in Paraná. Data collection took place in June/2017, through recorded semi-structured interviews, based on the guiding question: could tell me about the use of the infusion pump in your daily work? As for the transcribed data, Content Analysis was employed. Results: positive and negative aspects were highlighted regarding the use of the infusion pump, besides general suggestions for its purpose. Final considerations: although the interviewees perceive the Infusion Pump as a viable way for the assertiveness in volemic infusion, there are disadvantages related to the drop and alarm sensor. As for suggestions for improvements, it was mentioned the need to optimize the design of the Infusion Pump, especially the alarm programming.


Objetivo: analizar las percepciones de los profesionales de enfermería sobre el uso de la Bomba de Infusión en su vivir cotidiano en Cuidados Intensivos. Método: estudio descriptivo-exploratorio con enfoque cualitativo, realizado con 15 profesionales de enfermería de la Unidad de Cuidados Intensivos para Adultos de un hospital público de enseñanza en Paraná. La recopilación de datos ocurrió en junio/2017, mediante entrevistas semiestructuradas grabadas, basadas en la pregunta orientadora: ¿podrías contarme sobre el uso de la bomba de infusión en su trabajo cotidiano? Para los datos transcritos, se empleó el Análisis de Contenido. Resultados: se señalaron aspectos positivos y negativos acerca del uso de la bomba de infusión, además de sugerencias generales para su propósito. Consideraciones finales: aunque los entrevistados perciben que la Bomba de Infusión es viable para la asertividad en la infusión volémica, existen desventajas relacionadas con el sensor de gotas y alarma. Como sugerencias de mejoras, se mencionó la necesidad de perfeccionar el design de la Bomba de Infusión, especialmente la programación de alarmas.


Subject(s)
Humans , Infusion Pumps , Biomedical Technology , Patient Safety , Intensive Care Units , Nursing, Team
5.
Rev. Esc. Enferm. USP ; 54: e03562, 2020. tab, graf
Article in English, Portuguese | BDENF, LILACS | ID: biblio-1101392

ABSTRACT

Abstract Objective: To identify the scientific evidence on the frequency of handling errors of conventional and smart pump infusions in intravenous insulin therapy in intensive care units. Method: A systematic review with meta-analysis conducted in the Virtual Health Library, MEDLINE via PubMed, Scopus and Web of Science databases. Articles were assessed regarding the level of evidence by applying the Oxford Center for Evidence-Based Medicine Evidence Scale. Results: Twelve (12) publications were selected which met the eligibility criteria. The programming error rate using the conventional infusion pump ranged from 10% to 40.1%, and the smart pump technology error rate ranged from 0.3 to 14%. The meta-analysis of two studies favored the smart pump in reducing the relative risk of programming errors by 51%. Conclusion: Based on selected articles, the smart pump reduces the risk of programming errors.


Resumen Objetivo: Identificar las evidencias acerca de la frecuencia de errores en el manejo de las bombas de infusión convencional y smart pump en la terapia insulínica intravenosa en unidades de cuidados intensivos. Método: Revisión sistemática con metaanálisis llevada a cabo en las bases de datos Biblioteca Virtual de Saúde, MEDLINE por vía PubMed, Scopus y Web of Science. Los artículos fueron evaluados en cuanto al nivel de evidencia por la aplicación de la Escala de Evidencia del Oxford Centre for Evidence-Based Medicine. Resultados: Se seleccionaron 12 publicaciones que atendieron los criterios de elegibilidad. El índice de errores de programación utilizando la bomba de infusión convencional varió del 10% al 40,1% y en la tecnología smart pump varió del 0,3% al 14%. El metaanálisis de dos estudios fue favorable a la smart pump en la reducción del riesgo relativo de errores de programación en el 51%. Conclusión: Considerando como base los artículos seleccionados, la smart pump reduce el riesgo de errores de programación.


Resumo Objetivo: Identificar as evidências científicas acerca da frequência de erros no manuseio das bombas de infusão convencional e smart pump na terapia insulínica intravenosa em unidades de cuidados intensivos. Método: Revisão sistemática com metanálise realizada nas bases de dados Biblioteca Virtual de Saúde, MEDLINE via PubMed, Scopus e Web of Science. Os artigos foram avaliados quanto ao nível de evidência pela aplicação da Escala de Evidência do Oxford Centre for Evidence-Based Medicine. Resultados: Foram selecionadas 12 publicações que atenderam aos critérios de elegibilidade. A taxa de erros de programação usando a bomba de infusão convencional variou de 10% a 40,1% e na tecnologia smart pump variou de 0,3 a 14%. A metanálise de dois estudos foi favorável a smart pump na redução do risco relativo de erros de programação em 51%. Conclusão: Considerando como base os artigos selecionados, a smart pump reduz o risco de erros de programação.


Subject(s)
Infusion Pumps , Insulin/administration & dosage , Intensive Care Units , Medication Errors , Review , Critical Care Nursing
6.
Arq. gastroenterol ; 55(supl.1): 41-46, Nov. 2018. tab, graf
Article in English | LILACS | ID: biblio-973905

ABSTRACT

ABSTRACT BACKGROUND: High resolution anorectal manometry (HRAM-WP) allows more simplified, objective, and uniform data acquisition and interpretation of the test results. OBJECTIVE: To validate a HRAM under water perfusion (Alacer Biomédica) with a 24-channel probe and to compare the results of anorectal manometry with other systems. METHODS: Individuals without critical evacuation disorders were selected. Patients with incontinence, anal surgery, dyssynergia or sphincter injury were excluded. The test was performed with an Alacer Biomédica 24 channel manometry system under water perfusion, with a probe configured with 6 levels of 4 radial channels, separated from each other by 0.8 mm. The mean pressures for the functional channel were determined, in states of rest (RMP), contention effort (CMP) and evacuation effort (EEMP). The pressure extension of the sphincter was also tabulated in cm. The results were compared with those available in recent literature. RESULTS: Fifty patients were studied (20 men; 30 women). Overall, the following results were obtained: the RMP was 76.9±3.0 mmHg, the CMP was 194.2±9.4 mmHg, and EEMP was 88.2±3.7 mmHg. When classified according to the gender, for men: RMP was 72.2±3.0 mmHg, CMP was 229.5±17 mmHg, and EEMP was 91.4±7.0. For women, RMP was 79.8±4.0 mmHg, CMP was 170.7±8, and EEMP was 86.1±4.3 mmHg. The sphincter gauge extension for both genders was 3.1±0.09 cm (men 3.3±0.1; women 3.0±0.1). DISCUSSION: Studying HRAM-WP has become much easier. Non-mobilization of the sensor causes less discomfort and artefacts with a lower assessment time. In this study, small differential values between both sexes during rest were observed, highlighting a greater containment force in men. No difference in sphincter extension was noted. The results of this study are consistent with that of existing reports and with those obtained using solid state probes. CONCLUSION: The perfusion system yielded results similar to that of solid state systems. Further studies to evaluate parameters with respect to pelvic dyssynergia and incontinence need to be conducted. Additionally, to determine if the vector volume can furnish new information in terms of functional and anatomical aspects.


RESUMO CONTEXTO: Através da manometria anorretal de alta resolução (MARAR), a aquisição dos dados e a interpretação do exame tornaram-se mais simplificadas, objetivas e uniformes. OBJETIVO: Validar um sistema de MARAR sob perfusão de água (Alacer Biomédica), com sonda de 24 canais e comparar resultados dos exames de manometria anorretal com outros sistemas em trabalhos já publicados. MÉTODOS: Selecionados indivíduos sem distúrbio evacuatório importante. Excluídos pacientes com incontinência, cirurgia orificial, dissinergia, ou lesão esfincteriana. O exame foi realizado com sistema Alacer Biomédica de manometria sob perfusão de agua de 24 canais, com sonda configurada com 6 níveis de 4 canais radiais, distanciados entre si por 0,8 mm. Estabelecidas as pressões médias para o canal funcional, nos estados de repouso (PMR), no esforço de contenção (PMC) e no esforço evacuatório (PMEE). Também foi tabulada a extensão pressórica do esfíncter em cm. Comparou-se os resultados com os disponíveis em literatura recente. RESULTADOS: Foram estudados 50 pacientes (20 masc; 30 fem). No geral, foram encontrados os seguintes resultados: a PMR foi de 76,9±3,0 mmHg; PMC foi de 194,2±9,4 mmHg e; PMEE foi de 88,2±3,7 mmHg. Quando divididos por sexo: sexo masculino: PMR 72,2±3,0 mmHg; PMC: 229,5±17 mmHg e; PMEE 91,4±7,0. Sexo feminino: PMR 79,8±4,0 mmHg; PMC: 170,7±8; PMEE 86,1±4,3 mmHg. A extensão manométrica para ambos os sexos foi de 3,1±0,09 cm (masc 3,3±0,1; fem 3,0±0,1). DISCUSSÃO: A realização do estudo da MARAR ficou muito facilitada. A não mobilização da sonda provoca menos desconforto e artefatos, com menor tempo de estudo. Em nossa série há valores diferenciais pequenos entre os sexos durante o repouso, destacando-se maior força de contenção no sexo masculino. Não houve diferença para a extensão do esfíncter. Em relação à comparação com os estudos já publicados, mesmo com sondas de solid state, há uma proximidade de valores. CONCLUSÃO: O sistema de perfusão utilizado permitiu reproduzir resultados similares a sistemas solid state. Resta estabelecer parâmetros em casos de dissinergia pélvica, incontinência e esclarecer se o estudo pelo vetor volume pode trazer novas informações nos aspectos funcional e anatômico.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Aged , Aged, 80 and over , Young Adult , Anal Canal/diagnostic imaging , Rectum/diagnostic imaging , Endosonography/methods , Fecal Incontinence/diagnostic imaging , Brazil , Retrospective Studies , Endosonography/instrumentation , Imaging, Three-Dimensional , Middle Aged
7.
Rev. latinoam. enferm. (Online) ; 26: e3053, 2018. tab, graf
Article in English | LILACS, BDENF | ID: biblio-961159

ABSTRACT

ABSTRACT Objective: To evaluate the hemolysis biomarkers of packed red blood cells transfused by two different linear peristaltic infusion pumps at two infusion rates. Method: An experimental and randomized study was designed simulating the clinical practice of transfusion. Two linear peristaltic infusion pumps from different manufactures were studied in triplicate at 100 mL/h and 300mL/h infusion rates. The chosen hemolysis biomarkers were total hemoglobin, free hemoglobin, hematocrit, potassium and degree of hemolysis. They were analyzed before and after each infusion. Results: Potassium showed statistically significant variations in all scenarios of the experiment (P<0.010). In a separated analysis, potassium increased mainly at 300mL/h rate (P=0.021) and free hemoglobin had significant variation when comparing infusion pumps from different manufacturers (P=0.026). Although hematocrit, total hemoglobin and degree of hemolysis had increased after infusion, no statistically significance variations were identified. Conclusions: Hemolysis risk induced by a linear peristaltic infusion pump was identified by an increase in free hemoglobin and potassium markers. As the potassium biomarker is often increased in aged packed red blood cells, we do not recommend using them in this scenario. Additional studies should be performed about other markers and using larger samples in order to reinforce the transfusion practice in nursing.


RESUMO Objetivo: avaliar os biomarcadores de hemólise de concentrado de hemácias transfundidos por duas bombas de infusão peristáltica linear distintas, em duas taxas de infusão. Método: estudo experimental randomizado desenhado para simular a prática clínica da transfusão. Duas bombas de infusão peristáltica linear de diferentes fabricantes foram estudadas em triplicata a 100 ml/h e 300 mL/h de infusão. Os biomarcadores de hemólise escolhidos foram hemoglobina total, hemoglobina livre, hematócrito, potássio e grau de hemólise. Eles foram analisados antes e após cada infusão. Resultados: o potássio apresentou variações estatisticamente significativas em todos os cenários do experimento (P < 0,010). Em análise separada, o potássio aumentou principalmente na taxa de 300 mL/h (P = 0,021) e a hemoglobina livre teve uma variação significativa no experimento comparando bombas de infusão de diferentes fabricantes (P = 0,026). Embora o hematócrito, a hemoglobina total e o grau de hemólise tenham aumentado após a infusão, não foram identificadas variações estatisticamente significativas. Conclusões: o risco de hemólise induzido por bombas de infusão peristáltica linear foi identificado com base em um aumento nos marcadores de hemoglobina livre e potássio. Como o biomarcador potássio é frequentemente aumentado em concentrados de hemácias envelhecidos, não se recomenda usá-los nesse cenário e estudos adicionais podem ser realizados. Vale a pena realizar estudos sobre outros marcadores e utilizar amostras maiores para fundamentar a prática de enfermagem transfusional.


RESUMEN Objetivo: evaluar los biomarcadores de hemólisis de concentrados de glóbulos rojos transfundidos por dos bombas de infusión peristálticas lineales diferentes a dos velocidades de infusión. Método: se hizo un estudio experimental y aleatorizado que simula la práctica clínica de la transfusión. Se estudiaron dos bombas de infusión peristálticas lineales de diferentes fabricantes por triplicado a velocidades de infusión de 100 ml/h y 300 ml/h. Los biomarcadores de hemólisis elegidos fueron la hemoglobina total, la hemoglobina libre, el hematocrito, el potasio y el grado de hemólisis. Fueron analizados antes y después de cada infusión. Resultados: El potasio mostró variaciones estadísticamente significativas en todos los escenarios del experimento (P <0.010). En análisis separados, el potasio aumentó principalmente a una tasa de 300 ml/h (P=0.021) y la hemoglobina libre tuvo una variación significativa en un experimento de un fabricante de bomba de infusión (P=0.026). Aunque el hematocrito, la hemoglobina total y el grado de hemólisis aumentaron después de la infusión, no se identificaron variaciones estadísticamente significativas. Conclusiones: el riesgo de hemólisis inducido por una bomba de infusión peristáltica lineal se identificó por un aumento en la hemoglobina libre y los marcadores de potasio. Debido a que el biomarcador de potasio a menudo aumenta en los glóbulos rojos concentrados de edad, no recomendamos utilizarlos en este escenario y se podrían realizar estudios adicionales. Vale la pena realizar estudios sobre otros marcadores y el uso de muestras más grandes para fundamentar la práctica de enfermería de transfusión de sangre.


Subject(s)
Humans , Male , Female , Blood Transfusion/methods , Erythrocytes/immunology , Hemolysis , Infusion Pumps , Patient Safety
8.
Rev. bras. enferm ; 70(3): 595-601, May-June 2017.
Article in English | LILACS, BDENF | ID: biblio-843666

ABSTRACT

ABSTRACT Objectives: To identify what are the difficulties of the nursing staff in the management of technologies during intravenous therapy (IVT) and discuss the difficulties identified under the perspective of patient's safety. Method: Descriptive study of qualitative approach with data collected by semi-structured interview and analyzed by the Alceste software. Results: The greatest difficulty of cognitive and technical emphasis was the lack of training; and regarding administrative emphasis, the greatest difficulty was the lack of material and human resources. Infusion pumps and their proper use were highlighted as the technological resource that most contributed to patient safety. Final considerations: The lack of training is presented as the greatest difficulty of nursing professionals and permeates safety issues of both patient and professional when using the hard technologies in IVT. Training is essential to the development of techniques, considered nursing tools.


RESUMEN Objetivos: Identificar las dificultades del personal de enfermería en utilizar tecnologías durante la terapia intravenosa (TIV) y discutir las dificultades encontradas bajo el punto de vista de la seguridad del paciente. Método: estudio cualitativo, de tipo descriptivo, en el cual se empleó entrevista semiestructurada para la recolección de los datos y los analizó por el programa Alceste. Resultados: La dificultad de énfasis cognitiva y técnica más frecuente fue la ausencia de capacitación para utilizar la tecnología; y la de énfasis administrativa fue la ausencia de recursos materiales y humanos. El recurso tecnológico que más contribuye para garantizar la seguridad del paciente fue las bombas de infusión y su correcto empleo. Consideraciones finales: El personal de enfermería relató que la ausencia de capacitación es la dificultad que más enfrentan, y que les va a influir en la seguridad del paciente y del profesional al emplear las tecnologías en la TIV. Las capacitaciones son esenciales para el desarrollo de las técnicas, consideradas las herramientas de hacer enfermería.


RESUMO Objetivos: Identificar quais são as dificuldades da equipe de Enfermagem no manejo das tecnologias durante a terapia intravenosa (TIV) e discutir as dificuldades identificadas sob a perspectiva da segurança do paciente. Método: abordagem qualitativa, do tipo descritivo com dados coletados por entrevista semiestruturada e analisados pelo programa Alceste. Resultados: A maior dificuldade de ênfase cognitiva e técnica foi a falta de treinamento; e de ênfase administrativa, foi a falta de recursos materiais e humanos. As bombas de infusão e sua utilização adequada foram destacadas como o recurso tecnológico que mais contribuiu para a segurança do paciente. Considerações finais: A falta de treinamento é apresentada como a maior dificuldade dos profissionais de Enfermagem e permeia as questões de segurança do paciente e do profissional ao utilizar as tecnologias duras na TIV. O treinamento é imprescindível para o desenvolvimento das técnicas, consideradas como ferramentas do fazer da Enfermagem.


Subject(s)
Humans , Infusions, Intravenous/instrumentation , Infusions, Intravenous/standards , Patient Safety/standards , Nursing, Team/standards , Teaching/standards , Chi-Square Distribution , Clinical Competence/standards , Qualitative Research , Hospitals, University/organization & administration , Intensive Care Units/organization & administration , Nurses/standards
9.
J. health inform ; 8(2): 66-72, abr.-jun. 2016. ilus, tab, graf
Article in Portuguese | LILACS | ID: biblio-1112

ABSTRACT

Objetivo: Este artigo apresenta o sistema de monitoramento de soro hospitalar OpenSerum. Trata-se de uma solução open source que faz uso de tecnologias de comunicação móvel para o acompanhamento em tempo real do serviço de infusão intravenosa de soro hospitalar. Método: Na primeira etapa, montou-se um circuito elétrico baseado em sensores infravermelhos para a monitoração da queda das gotas. Na segunda etapa, codificou-se um sistema servidor capaz de manter dados de configuração e enviar mensagens de texto informativas de status para dispositivos móveis cadastrados.  Resultados: O sistema de monitoramento permitiu detectar, por meio de mudanças na faixa de valores analógicos do receptor infravermelho, se o soro estava em atividade ou não. Conclusão: O sistema desenvolvido cumpriu com seus objetivos de monitoração, destacando a capacidade de interação com dispositivos móveis quando necessário para informar o status de atividade do soro monitorado.


Objectives: This paper presents the OpenSerum system for serum monitoring. It is an open source solution that uses mobile communication technologies for real-time monitoring of intravenous serum infusion service. Method: First, an electrical circuit was assembled based on infrared sensors in order to detect the fall of drops. Next, a server system was programed in order to maintain circuit configuration data and send textual messages with status information for mobile devices. Results: The monitoring system allows the detection, through changes in the range of analog infrared receiver values, whether the serum was active or not. Conclusion: The developed system reached its monitoring goals, highlighting the ability to interact with mobile devices when necessary to inform the serum activity status.


Objetivo: Ese artículo presenta el sistema de monitoreo de suero OpenSerum, una solución open source que hace uso de tecnologías de comunicación móviles para la monitorización en tiempo real de la infusión intravenosa de suero. Método: En la primera etapa, se creó un circuito eléctrico basado en sensores de infrarrojos para el seguimiento de la caída de las gotas. En la segunda, un sistema de servidor fue programado con el fin de mantener los datos de configuración de circuitos y enviar mensajes de texto con información de estado para dispositivos móviles. Resultados: El sistema de monitoreo permitió detectar por medio de cambios en la escala de valores analógicos del receptor infrarrojo, si el suero era o no en actividad. Conclusión: El sistema desarrollado cumplió con sus objetivos de monitoreo, poniendo de relieve la capacidad de interacción con dispositivos móviles cuando necesario para informar el status de actividad del suero.


Subject(s)
Infusion Pumps , Medical Informatics , Signal Processing, Computer-Assisted , Drug Monitoring , Biomedical Technology
10.
Rev. latinoam. enferm. (Online) ; 24: e2763, 2016. graf
Article in English | LILACS, BDENF | ID: biblio-960982

ABSTRACT

ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. Results: all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. Conclusion: infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies.


RESUMO Objetivos: identificar na literatura a produção científica acerca dos efeitos de bomba de infusão na administração de hemácias e avaliar as implicações do uso desses equipamentos na prática transfusional de enfermagem. Método: revisão integrativa de literatura nas bases de dados Pubmed/Medline, Scopus, Biblioteca Virtual em Saúde, SciELO, Web of Science e Cochrane, utilizando os descritores "bombas de infusão", "transfusão de sangue", "transfusão de eritrócitos" e "hemólise". A data inicial não foi delimitada e a final foi dezembro de 2014. Foram identificados 17 artigos de acordo com os critérios de inclusão e exclusão. Resultados: Todas as publicações incluídas eram estudos experimentais in vitro e abordavam o uso de bombas de infusão na terapêutica transfusional. A síntese dos dados foi apresentada em quadro sinóptico e a análise gerou duas categorias relevantes: lesão celular e mecanismo de infusão. Conclusão: bombas de infusão podem ser deletérias às hemácias de acordo o mecanismo de infusão, sendo que as peristálticas lineares foram mais predisponentes à hemólise. A lesão celular foi relacionada à liberação plasmática de marcadores, predominando a hemoglobina livre e potássio. Reitera-se a necessidade de pesquisas adicionais e investimentos tecnológicos para nortear o desenvolvimento de protocolos que promovam prática segura e que subsidiem futuros estudos clínicos.


RESUMEN Objetivos: identificar en la literatura la producción científica acerca de los efectos de la bomba de transfusión en la administración de glóbulos rojos y evaluar las implicaciones del uso de esos equipos en la práctica transfusional de enfermería. Método: revisión integradora de literatura en las bases de datos Pubmed/Medline, Scopus, Biblioteca Virtual en Salud, SciELO, Web of Science y Cochrane, utilizando los descriptores "bombas de infusión", "transfusión de sangre", "transfusión de eritrocitos" y "hemolisis". La fecha inicial no fue delimitada y la final fue en diciembre de 2014. Fueron identificados 17 artículos de acuerdo con los criterios de inclusión y exclusión. Resultados: todas las publicaciones incluidas eran estudios experimentales in vitro y abordaban el uso de bombas de infusión en la terapéutica transfusional. La síntesis de los datos se presenta en un cuadro sinóptico y el análisis generó dos categorías relevantes: lesión celular y mecanismo de transfusión. Conclusión: las bombas de infusión pueden ser perjudiciales para los glóbulos rojos de acuerdo el mecanismo de transfusión, siendo que las peristálticas lineares fueron más predisponentes para la hemolisis. La lesión celular fue relacionada a la liberación plasmática de marcadores, predominando la hemoglobina libre y el potasio. Se reitera la necesidad de realizar investigaciones adicionales e inversiones tecnológicas que puedan orientar el desarrollo de protocolos que promuevan la práctica segura y que ayuden a futuros estudios clínicos.


Subject(s)
Humans , Infusion Pumps/adverse effects , Erythrocyte Transfusion/instrumentation , Erythrocytes/pathology , Hemolysis
11.
Diagn. tratamento ; 19(3): 110-114, set. 2014. graf
Article in Portuguese | LILACS | ID: lil-720027

ABSTRACT

Contexto e objetivos: Estudos sugerem que a utilização da bomba centrífuga na circulação extracorpórea é melhor do ponto de vista fisiológico se comparada a bomba de rolete nos pacientes submetidos a cirurgia cardíaca. O objetivo do trabalho é avaliar os níveis séricos delactato em pacientes submetidos a cirurgia de revascularização do miocárdio utilizando as bombas de rolete e centrífugas durante a circulação extracorpórea (CEC) como um marcador prognóstico. Desenho e local: Trata-se de um estudo observacional retrospectivo, baseado em levantamento de dados de prontuários médico hospitalares, realizado no Hospital Sírio-Libanês. Método: Foi estudada uma coorte histórica de pacientes, dividida em dois grupos: o primeiro grupo, de 61 pacientes, operados no período de março de 2007 a julho de 2008, com bomba rolete, e o segundo grupo, de 74 pacientes, no período de julho de 2008 a fevereiro de 2011, com bomba centrífuga. As amostras sanguíneas dos pacientes foram colhidas em quatro diferentes tempos durante a operação: pré-circulação extracorpórea (T1); hipotermia a 32 °C (T2); hipotermia a 34 °C (T3); pós-circulação extracorpórea (T4). Resultados: Houve diferença significativa na amostra do lactato em T4 (P = 0,049). Conclusão: Na bomba centrífuga, observamos melhora do lactato ao final da circulação extracorpórea em comparação com a bomba rolete.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Centrifugal Pumps , Cohort Studies , Myocardial Revascularization
12.
Rev Rene (Online) ; 14(6): 1217-1223, nov.-dez. 2013. ilus
Article in Portuguese | LILACS, BDENF | ID: lil-721900

ABSTRACT

Estudo qualitativo cujo objetivo foi descrever a percepção do paciente oncológico em relação à utilização de um dispositivo para infusão contínua de quimioterápico, realizado com oito pacientes, por meio de entrevista semiestruturada com a questão norteadora: “Como você se sente utilizando dispositivo para infusão contínua de quimioterápico?”. Três categorias emergiram: evitando a hospitalização; desvendando o desconhecido; e desempenho de atividades. O paciente destaca o benefício de ir para casa e a possibilidade de realizar atividades, apesar da ansiedade quanto à presença do dispositivo e experiência nova em seu cotidiano. Os resultados foram importantes para direcionar as orientações relativas aos aspectos positivos e negativos dessa tecnologia.


This is a qualitative study whose aim was to describe the perception of an oncologic patient regarding the use of a device for continuous infusion of a chemotherapeutic agent. It was carried out with eight patients, through a semi-structured interview with this guiding question: “How do you feel about using a device for continuous infusion of a chemotherapeutic agent?”. Three categories emerged: avoiding hospitalization; unveiling the unknown; and performing activities. The patient highlights the benefit of going home and the possibility of performing activities, despite the anxiety regarding the presence of the device and the new experience in her/his daily life. The results were important to direct the guidelines related to the positive and negative aspects of this technology.


Estudio cualitativo cuyo objetivo fue describir la percepción del paciente oncológico con relación a la utilización de un dispositivo para infusión continua de quimioterápico, con ocho pacientes, a través de entrevista semiestructurada con la pregunta orientadora: “¿Cómo te sientes utilizando un dispositivo para infusión continua de droga de quimioterapia?”. Tres categorías emergieron: evitar la hospitalización; desvelar lo desconocido; y desarrollo actividades. El paciente destaca el beneficio de ir a casa y la posibilidad de realizar actividades, a pesar de la ansiedad en cuanto a la presencia del dispositivo y a la experiencia nueva en su cotidiano. Los resultados fueron importantes para hacer direccionar a las orientaciones relativas a los aspectos positivos y negativos de esta tecnología.


Subject(s)
Humans , Male , Female , Nursing , Medical Oncology , Drug Therapy
13.
Rev. bras. eng. biomed ; 29(4): 353-362, dez. 2013. tab
Article in Portuguese | LILACS | ID: lil-697282

ABSTRACT

INTRODUÇÃO: Entre os riscos intrínsecos na assistência à saúde, a infusão de medicamentos é uma preocupação constante. Essa pesquisa analisou os tipos de notificações de eventos adversos, com a possibilidade dos profissionais envolvidos no uso incorreto de operação de Bombas de Infusão (BI). Os autores realizaram uma pesquisa dos problemas decorrentes de eventos adversos gerados da utilização de BI e desenvolveram um instrumento de identificação de conhecimentos de habilidades e usabilidades de BI. MÉTODOS: A metodologia utilizada no estudo foi desenvolvida em quatro fases. Na primeira e segunda fase, realizou-se uma pesquisa no banco de dados de relatos sobre notificações na unidade de Tecnovigilância da Agência Nacional de Vigilância Sanitária (ANVISA) com o levantamento de dados, classificação de equipamentos, tipificação de problemas e análise de causas comuns. Na terceira fase realizou-se a análise do banco de dados de notificações de um fabricante de BI. Na última fase foi feita a análise de causas comuns para desenvolver as ações preventivas e o desenvolvimento do instrumento proposto. RESULTADOS: Foram analisados os anos de 2006 a 2011 onde existiam 1.971 relatos sobre notificações de equipamentos médicos hospitalares, sendo 251 desses relatos sobre BI (12,6%). Essa porcentagem foi a maior encontrada entre todos os equipamentos notificados. CONCLUSÃO: O estudo permitiu afirmar que os profissionais que operam as BI, muitas vezes possuem carência de conhecimento e/ou falta de compromisso com a atividade. Pode-se afirmar que um aspecto importante e inquestionável sobre o uso de BI é a relação com a segurança.


INTRODUCTION: Among the inherent risks in health care, the infusion of drugs is a constant concern. This research examined the types of notification of adverse events, with the possibility of the health professionals involved in the incorrect use of Infusion Pumps (IP) operation. The authors conducted a research of the problems arising from adverse events generated using IP and developed an instrument to identify the skills and knowledge of BI usability. METHODS: The methodology used in the study was developed in four phases. In the first and second phases, we carried out a search in the database of reports on notification in technovigilance unit of the Brazilian Health Surveillance Agency (ANVISA) with data collection, equipment classification, classification and analysis of problems of common causes. In the third phase took place the analysis of the database of notification from an IP manufacturer. In the last phase an analysis was made of the common causes for developing preventive actions and the development of the proposed instrument. RESULTS: We analyzed the years 2006 to 2011 where there were 1.971 reports of medical equipment notification, and 251 of these reports on IP (12.6%). This percentage was the highest among all equipment reported. CONCLUSION: The study allowed us to say that the professionals who operate the IP often denote lack of knowledge and / or lack of commitment to the activity. It can be argued that an important and unquestionable aspect about the use of IP is related to safety.

14.
J. pediatr. (Rio J.) ; 83(5,supl): S146-S154, Nov. 2007. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-470326

ABSTRACT

OBJETIVO: Revisar as novas opções nas terapêuticas insulínicas para controlar o diabetes melito de crianças e adolescentes. FONTES DOS DADOS: Foram revisados artigos indexados no PubMed buscados conforme as palavras insulin analogs in children and adolescents e incluídas informações contidas nos consensos da American Diabetes Association e Sociedade Brasileira de Diabetes. SÍNTESE DOS DADOS: São apresentadas informações sobre os novos análogos da insulina e, para comparação, são também revisadas as outras diferentes modalidades de insulina que estão atualmente disponíveis, focalizando nas terapias insulínicas que tentam fornecer uma aproximação mais fisiológica das estratégias basal-bolos no tratamento. Com o objetivo de obter melhor controle metabólico, mais e mais crianças estão em regimes de múltiplas injeções diárias ou usando infusões subcutâneas contínuas de insulina. Atingir controle glicêmico ótimo nas crianças é difícil devido ao maior risco de hipoglicemia decorrente da grande variabilidade em hábitos de ingerir alimentos e em níveis de atividade física. Se aplicados em bolos, subcutâneos, no diabetes tipo 1, os análogos de ação rápida, comparados com insulina humana regular, geralmente reduzem os episódios de hipoglicemia e glicemia pós-prandial, enquanto os análogos basais tendem a reduzir particularmente a hipoglicemia noturna. CONCLUSÃO: Embora os benefícios nos desfechos individuais metabólicos e clínicos pareçam modestos, a maioria dos estudos demonstra benefícios quando são usados análogos de insulina no tratamento do diabetes tipo 1 ou 2.


OBJECTIVE:To review the new options in insulin therapy for controlling diabetes mellitus in children and adolescents. SOURCES: Articles indexed in PubMed were located using the search terms insulin analogs in children and adolescents and reviewed. Information was also obtained from American Diabetes Association and Sociedade Brasileira de Diabetes consensus documents. SUMMARY OF THE FINDINGS: Information is presented on new analogs of insulin and, for purposes of comparison, the other insulin modalities currently available are also reviewed, focusing on insulin therapies which attempt to approximate basal-bolus treatment strategies to physiology. With the objective of obtaining improved metabolic control, more and more children are being put on multiple daily injection regimes or using continuous subcutaneous insulin infusion. It is difficult to achieve optimum glycemic control in children due to the increased risk of hypoglycemia resulting from the great variability in dietary intake habits and in physical activity levels. With diabetes type 1, if rapid-acting analogs are given subcutaneously in bolus, they generally reduce hypoglycemia episodes and postprandial glycemia levels, compared with regular human insulin, while basal analogs tend to reduce particularly the number of episodes of nocturnal hypoglycemia. CONCLUSIONS: Although the benefits to individual metabolic and clinical outcomes appear modest, the majority of studies demonstrate benefits when insulin analogs are used in the treatment of diabetes type 1 or 2.


Subject(s)
Adolescent , Child , Humans , Diabetes Mellitus/drug therapy , Hypoglycemic Agents/therapeutic use , Insulin Infusion Systems , Insulin/therapeutic use , Blood Glucose/analysis , Critical Care , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/drug therapy , /blood , /drug therapy , Hypoglycemia/drug therapy , Hypoglycemia/etiology , Infusion Pumps, Implantable , Injections, Subcutaneous , Insulin/analogs & derivatives
15.
Rev. bras. hematol. hemoter ; 29(2): 149-152, abr.-jun. 2007. ilus, tab
Article in Portuguese | LILACS | ID: lil-467874

ABSTRACT

A lise das hemácias, de causa imune ou não imune, pode provocar a elevação da hemoglobina plasmática induzindo efeitos deletérios principalmente nos rins e no sistema cardiovascular. Este trabalho objetiva evidenciar o possível efeito hemolítico induzido pelo trauma mecânico provocado pela passagem das hemácias em diferentes modelos de bombas de infusão de soluções, em concentrados de hemácias com até dez dias de armazenamento, preparados com Sag-Manitol. Foram utilizados três modelos de bombas (Nutrimat, Infusomat Compact e Volumed), com quatro aparelhos de cada modelo, testados em três velocidades de infusão (120 mL/h, 240 mL/h e 360 mL/h). Os parâmetros utilizados para evidenciar o grau de hemólise foram o percentual de hemólise e os níveis de hemoglobina e potássio livres no plasma. As amostras foram coletadas antes da passagem do concentrado de hemácias pelas bombas, na metade do tempo de infusão e no final da infusão, nas diferentes velocidades. Não ocorreu variação significativa entre os valores dos parâmetros analisados nas amostras controle e naquelas coletadas nas diferentes velocidades, marcas de bombas, mecanismos de infusão entre as bombas da mesma marca e entre os diferentes tempos de infusão. A principal variação encontrada foi relacionada com o potássio livre, devido à variação inerente aos próprios concentrados, o que foi evidenciado ao se compararem os valores obtidos nas amostras controle e nas amostras colhidas nos tempos médio e final em cada bomba. De acordo com os resultados obtidos, não houve alteração estatisticamente significativa do percentual de hemólise após a passagem pelas bombas de infusão nos modelos analisados.


The lyses of red blood cells, both for immune or non-immune reasons, can cause an elevation in plasmatic hemoglobin, inducing harmful effects mainly in the kidneys and cardiovascular system. This work aims at identifying the possible hemolytic effect, related to mechanical trauma due to the use of different models of infusion pumps, on red blood cells transfused after up to ten days of storage. Three models of pumps were studied (Nutrimat, Infusomat Compact and Volumed), (four devices of each model) with three infusion speeds being tested (120 mL/h, 240 mL/h and 360 mL/h). The parameters used to report the degree of hemolysis were the percentile of hemolysis, hemoglobin levels and free potassium in the plasma. Samples were collected before infusion of red blood cells using the pumps, half way through infusion (1/2 T) and at the end of infusion (T), for the three different speeds. Significant variations were not seen in the analyzed parameters between the control samples and those collected at different speeds, using different models of pumps and infusion mechanisms and among pumps of the same brand and at different infusion times. The greatest variation found involved free potassium, probably due to the different levels found in red blood cell concentrates seen when control samples were compared to values obtained half way through and at the end of infusion for each pump. In agreement with the obtained results changes in the percentile of hemolysis were not found after infusion of the cells using the different infusion pumps.


Subject(s)
Hemolysis , Blood Transfusion , Infusion Pumps , Erythrocytes
SELECTION OF CITATIONS
SEARCH DETAIL